Choices..Nov 07, 2007


"...a house in the idillic mountains of PR where I can raise chickens, potatoes and plaintains and perhaps a cow to milk.." sounds tempting!

Anyway, oil price this morning is at $2.7983 per gallon for #2 oil. Last year during the heating peak, we were paying $2.29. I anticipate a price of above $3.20 PG in the peak of season. As AdC pointed out, someone has to pay for this.

Boards do not like to raise maintenance every time there is a price increase that was not anticipated, but times are changing and I believe larger and more time structures increases are to, and should be anticipated. Temporary fuel assessments and higher inflationary increases are becoming the norm. These reluctant boards are trying to make up for not raising the maintenance as much as they should by cutting corners elsewhere. Depending on the individual personality of your building, this may or may not be a good idea.

TIP:
Have an assessment done of your boiler, heat timer (and settings), riser & return lines, building envelope, insulation, etc. and remedy all areas needed. Through this I have been able to yield a 15 to even a 38% savings in one other building.

~AR

Join the Conversation Comments (2)
do this - sally Nov 07, 2007


also have nyserda do an energy audit of your building. it is subsidized and they will halep you save $. also write to the board and ask them to have the water bil checked. we just got 20k by doing this.

Thank you for rating!

You have already rated this page, you can only rate it once!

Your rating has been changed, thanks for rating!

Introduce yourself to other members of Board Talk! Login below or register here.

Board Talk members who registered prior to March 9th, 2016 will need to reset their password.

Register

Forgot your password? Click here

> Join the conversation
Heat issues - AdC Nov 07, 2007


Who is a good heat consultant to check for the distribution system?

AdC

Thank you for rating!

You have already rated this page, you can only rate it once!

Your rating has been changed, thanks for rating!

Introduce yourself to other members of Board Talk! Login below or register here.

Board Talk members who registered prior to March 9th, 2016 will need to reset their password.

Register

Forgot your password? Click here

> Join the conversation Comments (2)
We can stand the heat - - BP Nov 08, 2007


Interesting finding in our bldg. Our lobby is 30'x40" and not heated. It is of course warmer than outside in the winter, but people comment how cool it gets if they stop to chat with our doorman or linger for any reason. A door off the lobby goes to the back where our trash areas, laundry and bldg system rooms are. We recently emptied all the back rooms and had our exterminator locate and seal all holes, then the whole area was painted. There were a lot of holes and a few major fissures in boiler and oil tank room walls.

The purpose was pest control and long overdue maintenance but we're noticing how much warmer the lobby is. The walls and floors are marble so the lobby is cool even before temps really start dropping but the difference is already very noticeable.

Proof that sealing holes, etc. is a worthwhile effort. Our lobby is pleasantly warmer. As I said, it isn't heated but if it were, I'm sure the work we did would be saving us money on heating it.

Thank you for rating!

You have already rated this page, you can only rate it once!

Your rating has been changed, thanks for rating!

Introduce yourself to other members of Board Talk! Login below or register here.

Board Talk members who registered prior to March 9th, 2016 will need to reset their password.

Register

Forgot your password? Click here

> Join the conversation
10 Commandments - AR Nov 08, 2007


What I usually do, is have the oil distributor (Castle, Metro, etc..) perform an energy assessment (Free of charge), then I do the rest. I sometimes use Lane engineering for the physical envelope assessment. I perform the distribution, return and system analysis myself. so there is no company I can recommend (maybe I/we should start one!?)
I realize that does not help many people here, so I will explain a few (10) things that you can do yourself to help. Of course there are many more...

1. Ensure all heat risers and returns are insulated as adequately as possible including exposed risers in apartments that are not being used for heat.
2. Ensure all domestic hot water lines are adequately insulated.
3. Have the super turn OFF the automatic water feeder in the boiler. Place a piece of tape at the current fill line and wait 24 hours. Then see how much water was lost. In this weather, anything more than 1/2 inch is too much and may suggest a problem such as water leaks in the boiler (Leaks outside the system can be ascertained by checking the condensation on the pipes at this time), or your return lines. If you have a heat timer with a return line sensor on this line, your boiler is running extra cycles for nothing.
4. Remedy any deficiencies from #3.
5. Sometimes heat distribution is uneven throughout the building. Some will complain about too much heat, some too little. This can be a different cause in different buildings. Two of the most common are: missing radiators on a riser (usually due to previous construction): there will be uneven amounts of heat in each riser - the remedy - tap valves. Another reason is that the air vent valves on the radiator is the wrong size for the location of the radiator. many supers have a hard time figuring which valve to put where and as a result, use the same one everywhere. I found in 100% of the buildings i looked at, I had to replace and reset all the valves. This is a topic that I can almost write a book on!
6. Always make sure that from spring-fall your boiler is set to "low fire" and readjusted in heating season. Otherwise you are burning 2X the needed fuel during those times.
7. Have the tubes and system cleaned regularly (important)
8. Have the heads of the burner cleaned (the super should do this every month)
9. OK, I cannot legally say to do this, or that I do it... on a marginal weather day, your burner waste sometimes double the fuel than a day with solid cold. It will continue the heat cycles all day to establish a temperature that may only be 1-6 degrees above the out door temperature. "many supers I know will turn the boiler on Summer during these days" I do not even get complaints.
10. Shop your oil, don't be afraid just because you have a long term relationship.. that may just be why your over paying.

~AR

Thank you for rating!

You have already rated this page, you can only rate it once!

Your rating has been changed, thanks for rating!

Introduce yourself to other members of Board Talk! Login below or register here.

Board Talk members who registered prior to March 9th, 2016 will need to reset their password.

Register

Forgot your password? Click here

> Join the conversation

Introduce yourself to other members of Board Talk! Log in below or register here.

Board Talk members who registered prior to March 9th, 2016 will need to reset their password.

Introduce yourself to other members of Board Talk! Login below or register here.
Board Talk members who registered prior to March 9th, 2016 will need to reset their password.

Ask the Experts

learn more

Learn all the basics of NYC co-op and condo management, with straight talk from heavy hitters in the field of co-op or condo apartments

Professionals in some of the key fields of co-op and condo board governance and building management answer common questions in their areas of expertise

Source Guide

see the guide

Looking for a vendor?